Casmed CAS-740 Vital Signs Monitor
The Casmed CAS-740 Vital Signs Monitor offers proprietary Motion Artifact Extraction (MAXNIBPยฎ) technology provides quick accurate blood pressure readings for neonates through adults, as well as the most challenging situations like high motion or low perfusion.
Casmed CAS-740 Vital Signs Monitor Features
- Easy-to-use, reliable, accurate
- Multi-parameter capabilities
- Fast, accurate blood pressure readings for neonates through adults
- Reduces the problems of motion in blood pressure measurement
- Monitor oximetry and temperature either continuously or in a “spot-check” mode
- Covidien FasTemp Technology gives accurate oral temperature in exactly 4 seconds
- Ideal for
- medical or surgical patients on pain medications including PCA pumps
- hospitals
- office-based endoscopy procedures
- EMS market
- Casmed’s proprietary MAXNIBP technology
- Oximetry choices include
- Masimo SET
- Nellcor OxiMax
- Nonin
- Created with emergency medical responders in mind
- Wireless Infrared printer option
- (3) Power Options
- NiMH battery pack
- internal power supply
- DC power option
- Temperature module features Fever / Hypothermic Modes
- (4) models available
- CAS 740-1: MAXNIBP
- CAS 740-2: MAXNIBP and SPO2
- CAS 740-2T: MAXNIBP and Temperature
- CAS 740-3: MAXNIBP, SPO2 and Temperature
Casmed CAS-740 Vital Signs Monitor Specifications
PHYSICAL PARAMETERS
- Dimensions: 8-1/2″ W x 3″ D x 6-3/4″ H
- Weight: 3 lbs
NIBP
- Technique: Oscillometric MAXNIBP Technology
- Patient Range: Adult – Neonate
- Measurement Range
- Systolic: 30 – 255 mmHg
- Diastolic: 15 – 220 mmHg
- MAP: 20 – 235 mmHg
- Pulse Rate Range: 30 – 240 BPM
- Accuracy
- Blood pressure: ยฑ5 mmHg standard deviation no greater than 8 mmHg
- Pulse Rate: ยฑ2% or ยฑ2 BPM, whichever is greater
OPERATING MODES
- History: Review of previous measurements
- NIBP: Manual, STAT or Automatic
- %SPO2: Continuous Monitoring
- Temperature: Predictive or Direct
CONTROL PANEL
- Display: LED display of measurement results, instructions, troubleshooting messages, and signal strength bar
- Parameters Displayed: Systolic Pressure, Diastolic Pressure, Mean Arterial Pressure (MAP), Pulse Rate, %SPO2, Temperature ยฐC / ยฐF
PATIENT ALARMS
- Adjustable high and low alarms for Pulse Rate, SPO2, Systolic Pressure, Diastolic Pressure and Mean Arterial Pressure
POWER
- Source: External line or internal battery
- AC power: 100 – 240 VAC | 50 – 60 Hz | 0.5 A
- Fuse rating: T1.25A L250V
- DC Power: 12 – 30 VDC
- Battery: NiMH removable pack
- Charging time: 4 hours
- Operating time: minimum 4 hours of continuous operation
- Leakage current: 100 ยตA
Reviews
There are no reviews yet.